Acrel Ahkc-Ekaa Split Core Open-Loop Hall Effect Current Sensor with 4-20mA 24V Power Supply

Acrel Ahkc-Ekaa Split Core Open-Loop Hall Effect Current Sensor with 4-20mA 24V Power Supply

WBI224F21 uses the principle of electromagnetic induction and Hall effect to measure the AC and DC current in the power grid in real time.
Description
Technical Parameters

WBI224F21(4-20mA Hall Effect Sensor) uses the principle of electromagnetic induction and Hall effect to measure the AC and DC current in the power grid in real time. It uses average value conversion technology, precision constant current technology and linear temperature compensation technology to convert it into standard DC current (Iz) output. 


Applications:

   Suitable for the current measuring,

   Automatic monitoring and control,

   Electrical signal detection and modulation,

   Data acquisition.


                           Advantages of Hall Effect Sensor

Current TransformerHall Effect Sensor
Functionality Generally, only the AC current is enlarged or reduced according to a certain ratio. The   functions are relatively single. DC and AC can be fully compatible. It can measure AC and DC currents and output   industry standard signals.
SafetyIf the measured current suddenly increases, the induced current will often   increase sharply, which will cause the collected instrument to burn out due  to large current.Generally resistant to 120% FS, even if there is a sudden large current, because the input and output are isolated   from each other, the safety of the instrument can still be guaranteed.


How to choose hall effect sensor








1. Determine AC, DC or AC / DC.








2. Determine the detection current and voltage: 5mA-2000A; 100V-4000V, etc.








3. Determine the output signal: 0-5V, 0-10V, 1-5V, 1-10V, 4-20mA, 0-20mA, etc.








4. Confirm the auxiliary power: DC 12V, 24V, 9V-36V, 85V-265V (Default 24V power supply, special user specified).









Hot Tags: 4-20mA Hall Effect Sensor, China, suppliers, factory, price, 3 Phase AC Current Transducer 4 20mA, 4 20mA Output AC Current Transducer, DC Voltage Transducer With Digital Output, Voltage Transducer, DC Voltage Transducer With Analog Output, 10V 500V Input Electrical Isolation Transducer

Input: AC/DC 100A-300A;


Output: DC 4-20mA;


Auxiliary power supply: 12V or 24VDC;


Accuracy level: 1.0;


Frequency response: ±DC/20Hz~5kHz;


Response time: 300ms;


Quiescent current: 40mA;


Ambient temperature: -25 ° C ~ +70 ° C;