WBV332U01-S (MYWB Analog Voltage Sensor) converts DC input voltage into a load-independent DC output signal of 0–5V or 0–10V. The MYWB Analog Voltage Sensor adopts a modulation-demodulation isolation principle and an average measurement method for real-time measurement of DC voltage from a power grid or circuit.
Advantages:
Strong overload capability
High reliability
Fast response
High precision
Applications:
Voltage measurement
Automatic monitoring and control
Electrical signal detection and modulation
Data acquisition
Hot Tags: MYWB Analog Voltage Sensor, China, suppliers, factory, price, 4 20mA Output DC Voltage Transducer, CE Certification, 0 10V Output DC Voltage Transducer, AC DC Voltage Transducer, High Voltage High Isolation Voltage Transducer, 10mV 1000V Input
|
Rated input voltage |
10mV, 50mV, 75mV, 5V, 50V, 150V, 200V, 300V, 400V, 500V, 750V, 1000V DC |
|
Output signals |
0-5V, 0-10V DC |
|
Accuracy |
0.2% |
|
Input impedance |
approximate zero |
|
Responding time |
350ms |
|
Linear measuring range |
0 - 1.2 times of rated input current |
|
Over load capacity |
30 times of rated input current, 5s |
|
Static current |
30mA |
|
Power supply |
+12V, +24VDC |
|
Isolation Voltage |
≥2500V DC, for 1 minute |
|
Thermal drift |
200ppm/°C |
|
Ambient temperature |
-25℃~+70℃ |
|
Mounting type |
DIN rail 35mm mount or screw mount |
|
Material of shell |
ABS (According to UL94V-0) |
|
Protection of shell |
IP20 |
|
Protection class |
Surge: 2kV; Electrostatic discharge: 6kV/8kV; Electrical fast transient burst: 2kV. |
|
MTBF |
>50000h |
|
Weight |
90g |