The WBI023TK03-35 current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current sensor. It can really measure resolution 1000:1 and it is used for precision measurement of DC, AC and pulse current.

Electrical data(Ta=25℃±5℃)

Parameter/Type

WBI023TK03-35 Uni

Rated input (Ipn)

350

400

500

A

Measure range(Ip)

1200 (±24V,17Ω)

1200 (±24V,36Ω)

1500 (±24V,24Ω)

A

Turns ratio(Np/Ns)

1:2000

1:4000

1:5000

 

Measure resister

with ±15V

@±500Amax 30(max)

@±400Amax 100(max)

@±500Amax 91(max)

Ω

Measure resister

with ±18V

@±900Amax 8(max)

@±800Amax 30(max)

@±1000Amax 20(max)

Ω

Coil resister

@±500Amax 50(max)

@±400Amax 130(max)

@±500Amax 120(max)

Ω

Rated output current (Isn)

@±1200Amax 10(max)

@±800Amax 43(max)

@±1000Amax 33(max)

Ω

Supply voltage

15

40

50

Ω

Power consumption

175±0.2%

100±0.2%

100±0.2%

mA

Zero offset current

±15~±24

V

Offset current drift

≤20+IpX(Np/Ns)

mA

Response time

@Ip=0

≤±0.2

mA

Linearity

@ -40℃~85℃

≤±0.5

mA

Galvanic isolation

@100A/ μS,10%-90%

<1.0

μs

di/dt accurately followed

@Ip=0- ±Ipn

≤0.1

%FS

Bandwidth

@ 50HZ,AC,1min

6

KV

Rated input (Ipn)

>100

A/ μs

Measure range(Ip)

@ -3db

DC…100

KHz

 

Applications

●Variable speed drives

●Welding machine

●Battery supplied applications

●Uninterruptible Power Supplies (UPS)

●Electrochemical

 

Mechanical dimension(for reference only)

Hall Effect Transducer for SCR Control and UPS

2. General tolerance ±1mm

3. TBC-LTHB1:With Molex connector(Molex 22011042:5045-04AG,5051-04)

4. TBC-LTHB2: With DG300-5.0 connector

 

Directions for use

1.Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.

2.The primary conductor should be≤120℃.

3.The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.

4.The primary turns should be at the top of the sensor for the best magnetic coupling.

5.When the current will be measured goes through a sensor, the voltage will be measured at the output end. (Note: The false wiring may result in the damage of the sensor)

6.Custom design in the different rated input current and the output current are available.

 

Standards

●UL94-V0.

●EN60947-1:2004

●IEC60950-1:2001

●EN50178:1998

●SJ 20790-2000

General date

 

Value

Unit

Symbol

Operating temperature

-40~+85

ºC

TA

Storage temperature

-40~+125

ºC

TS

Mass (approx)

290

g

M

Characteristics chart

3