China DC Voltage Sensor with Analog Output Manufacturers Factory Suppliers
-
WBV332U05-S converts DC input pure voltage into a load independent output signal DC 0-5V or 0-10V. It has adopted modulation-demodulation isolation principle and average measurement method for...view more
-
WBV342U01-S converts pure DC input voltage into a load independent output signal DC voltage 0-5V or 0-10V. It has adopted modulation-demodulation isolation principle and average measurement method...view more
-
WBV342U01-S converts pure DC input voltage into a load independent output signal DC voltage 0-5V or 0~10V. It has adopted modulation-demodulation isolation principle and average measurement method...view more
-
WBV332U01-S converts pure DC input voltage into a load independent output signal DC voltage 0-5V or 0-10V.view more
-
WBV342U01-S converts pure DC input voltage into a load independent output signal DC voltage 0-5V or 0-10V. It has adopted modulation-demodulation isolation principle and average measurement method...view more
-
WBV332U05-S converts DC input pure voltage into a load independent output signal DC 0-5V or 0-10V. It has adopted modulation-demodulation isolation principle and average measurement method for...view more
-
WBV334U01-S converts DC input pure voltage into a load independent output signal DC 0-20mA or 4-20mA.view more
-
WBV332U01-S converts pure DC input voltage into a load independent output signal DC voltage 0-5V or 0-10V.view more
-
WBV344U01-S converts DC input pure voltage into a load independent output signal DC 0-20mA or 4-20mA. It has adopted modulation-demodulation isolation principle and average measurement method for...view more
-
WBV414U09 converts AC input voltage into a load independent output signal DC 4-20mA. It has adopted electromagnetic isolation principle and average measurement method for real time measurement of...view more
-
WBV342U01-S converts pure DC input voltage into a load independent output signal DC voltage 0-5V or 0~10V. It has adopted modulation-demodulation isolation principle and average measurement method...view more
• Analog Voltage Outputs for Sensed Parameters: o 50V/180A = 63.69mV / Volt 18.30mV / Amp o 50V/90A = 63.69mV / Volt 36.60mV / Amp o 13.6V/45A = 242.3mV / Volt 73.20mV / Amp •...
Apr 03, 2022 · Voltage input range: DC 0-25V; Voltage detection range: DC 0.02440V-25V; Output signal type: Analog; Voltage Analog Resolution: 0.00489V; Voltage sensor module pinout:...
DC Current Transducer Analog Signal Output RS485/RS232 Output Bi-directional Signal Output AC/DC Signal Output Fiber Optical Current Sensor 1000KA DC AC Voltage Transducer Analog...
DC Voltage Sensor with Analog Output WBV332U05-S converts DC input pure voltage into a load independent output signal DC 0-5V or 0-10V. It has adopted modulation-demodulation...
Current and Voltage Sensors (AC and DC) Current and voltage sensors, used for voltage and current monitoring, logging, or proof-of-operation applications, provide discrete or analog...
Dc Voltage Sensor With Analog Output WBV334U05-S WBV334U05-S converts input pulsating DC voltage into a load independent output signal DC (0)4-20mA. It has adopted modulation...
